Industrial panel mount monitor with IP65 sealed front panel, open frame and wide temperature options

SEETEC builds display and embedded-PC hardware — not finished machines — designed to be integrated into equipment built by system integrators and OEM manufacturers. Standard platforms run from 5" to 32", configured to your project: open frame or enclosed housing, sealed front panel, sunlight-readable brightness, resistive or capacitive touch, and wide-temperature operation. Where the application needs the computer inside the enclosure, the same open-frame platform is also built as an all-in-one panel PC.

Order a single piece to evaluate, or a hundred for a production run. Standard models ship in 7 days; customized configurations take around 25 days.

Start With One Piece

  • MOQ from 1 to 10 pcs, depending on model and configuration — enough to build a prototype without committing to a production batch.
  • Paid samples are credited against the follow-up production order, so evaluation is not a sunk cost.
  • 7-day lead time on standard models, which is what makes a sample-based evaluation schedule realistic.

Pricing is quoted per configuration rather than listed, because brightness, touch, bonding and housing changes move the cost materially. Send the application and the constraints, and our engineering team will come back with a configuration, a datasheet and a quotation.

Where These Displays Are Used

  • Equipment integration — machine control panels, test and inspection equipment, automation cabinets
  • Outdoor and semi-outdoor terminals — kiosks, self-service terminals, public information displays, charging stations
  • Transport and marine — vehicle-mount, vessel bridge and cabin displays, wide-input-voltage DC systems

How to Specify Your Configuration

Size and resolution. 5" to 32" in regular production, up to 3840×2160. If the enclosure is fixed, send the cut-out dimensions and we will match the panel to the opening rather than the other way round.

Readability. Standard brightness starts at 250 nits; sunlight-readable configurations run to 1000 and 2000 nits. For direct-sunlight installations, optical bonding removes internal reflection and fogging — specify it up front, as it changes the mechanical stack.

Touch. Resistive for gloved operation and single-point input; projected capacitive for multi-touch and gesture; infrared and SAW where the surface must stay uncoated. Touch type drives both the controller interface and the front-panel sealing method.

Mechanical and ingress. Open frame, panel/embedded, VESA, rack, wall, flush and enclosed IP-rated chassis. Sealed models are rated IP65 on the front face only — the rear housing is not rated, and the installation design has to account for that. We would rather state this plainly than let it be discovered during commissioning.

Mechanical Formats

Open frame with side mounting ears, 4:3 legacy panels and enclosed chassis versions are built from the same platform. The mechanical form is chosen first — it determines the cut-out, the depth behind the panel and the sealing method.

16:9 open frame industrial monitor with side mounting ears
16:9 open frame with side mounting ears
4:3 open frame industrial monitor for legacy equipment replacement
4:3 open frame for legacy 4:3 equipment
Open frame industrial monitor side view showing housing depth and connectors
Side profile: housing depth and connector placement

Project Supply Terms

Item Terms
Minimum order 1–10 pcs, depending on model and configuration
Samples Available at cost. The sample charge is credited against the follow-up production order.
Lead time Standard models: 7 days. Customized configurations: approximately 25 days.
Certification CE and RoHS as standard. FCC, UKCA and IEC 62368-1 certification can be arranged on a project basis; certification cost and lead time are quoted separately. Other standards on request.
Supply continuity Panel supply continuity commitment available for qualified OEM programs, to avoid mid-project obsolescence.
Warranty 12-month limited warranty covering manufacturing defects. Full warranty terms

Capability Matrix

Parameter Range
Size 5" – 32" (16 sizes in production)
Resolution 800×480 up to 3840×2160
Brightness 250 – 2000 nits, model dependent; higher on request
Operating temperature -20℃ to +70℃, model dependent
Touch Resistive / Projected capacitive / Infrared / SAW
Video input HDMI, VGA, DVI, DisplayPort, 3G-SDI, CVBS, YPbPr
Power input 9–36 V DC wide range (vehicle and cabinet supply)
Mounting Open frame, panel/embedded, VESA, rack, wall, flush, enclosed IP-rated chassis
Ingress protection IP65 on front face (sealed models); rear housing non-rated
Cooling Fan-less architecture — no fan as a failure point
Embedded PC option All-in-one panel PC on the same open-frame platform; embedded controller with LAN, RS232 / RS485 and USB

OEM & Customization

From prototype validation to mass production, the following are configurable per project:

  • Optical bonding for sunlight readability and anti-fogging
  • Touch technology and controller interface selection
  • Brightness tuning and backlight configuration
  • Interface modification and added industrial I/O
  • Mechanical housing redesign and custom cut-out dimensions
  • Private-label branding and project documentation

Frequently Asked Questions

Do you supply single units, or only volume orders?

Both. Minimum order is 1 to 10 pcs depending on model and configuration, so a single unit for evaluation is possible. Paid samples are credited against the follow-up production order. Tell us the application and the quantity, and we will confirm the exact minimum for that configuration.

What is the real IP rating?

Sealed industrial models achieve IP65 on the front face. The rear housing is not rated for water or dust ingress — this is normal for panel-mount displays and has to be handled by the enclosure design. We state it explicitly so it is not discovered at commissioning.

Can the display be used outdoors in direct sunlight?

Yes, with the right configuration: 1000 or 2000 nits brightness plus optical bonding to eliminate internal reflection and fogging. For permanent outdoor installation, specify the sunlight and temperature profile of the site — it determines both the brightness target and the thermal design.

Can you match a fixed cut-out in an existing enclosure?

Yes. Send the opening dimensions, the depth available behind the panel, and the mounting method currently used. Mechanical customization of housing and cut-out is part of the standard engineering scope.

What certifications are available?

CE and RoHS as standard. FCC, UKCA and IEC 62368-1 can be arranged on a project basis, and other standards on request — certification is chargeable and quoted separately. Tell us the destination market and the required standard at the quotation stage, as certification affects both lead time and minimum quantity.

What happens if the panel is discontinued mid-project?

Supply continuity commitments are available for qualified OEM programs, covering long-life projects where a panel change would trigger re-qualification. This is agreed at project level, not per order.